SB TANDEM - Industrial Cleaner NILFISK - Free user manual and instructions
Find the device manual for free SB TANDEM NILFISK in PDF.
User questions about SB TANDEM NILFISK
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Industrial Cleaner in PDF format for free! Find your manual SB TANDEM - NILFISK and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. SB TANDEM by NILFISK.
USER MANUAL SB TANDEM NILFISK
Total Cleaning Confidence
Wichtige Sicherheitschinweise 2
GB Important safety notes. 4
F Consignes de sécurité importantes 6
NL Belangrijke veiligheidsinstrukties 8
① Avvertenze importanti per la sicurezza ... 10
Before putting the cleaner into operation, be sure to also read the enclosed operating instructions thoroughly and keep them close at hand for future reference.
The cleaner may only be used by persons trained in its use and expressly authorised to use it.
GENERAL
Operation of this cleaner is subject to the applicable national regulations.
In addition to these operating instructions and the binding regulations on accident prevention applicable in the country of use, the generally acknowledged technical rules for safe and correct working must also be observed.
Any method of work endangering health or safety is forbidden!
HEALTH-ENDANGERING DUSTS*)
This cleaner is not suitable for picking up health-endangered dusts.
FIRE AND EXPLOSION HAZARD


The following materials must not be picked up with the cleaner:
Hot materials (glowing cigarettes, hot ashes, etc.)
Inflammable, explosive or aggressive fluids (e.g. petrol, solvents, acids, alkalines, etc.)
Inflammable, explosive dusts (e.g. magnesium or aluminium dust, etc.).
APPLIANCE PLUG SOCKET
Before connecting any appliance to the appliance plug socket, the cleaner must always be switched off.
If appliances are connected to the appliance plug socket, ensure that these appliances are also switched off when being connected to the appliance plug socket.
CAUTION!
The operating instructions and the safety precautions contained therein must be observed when using appliances connected to the appliance plug socket of the cleaner.
USING FOR THE FIRST TIME
Before using the cleaner for the first time, check that it is in a good and safe condition.
Plugs and connectors of mains leads must be at least splash water-proof.
Check the mains connection and mains plug.
Inspect the mains lead at regular intervals for damage or signs of ageing. Use the cleaner only when the mains lead is in a good and safe condition.
(Damaged mains leads present a danger of electric shocks!)
Use the cleaner only with an undamaged filter element.
DURING OPERATION
Take care not to damage the mains lead (e.g. by driving over, pinching or dragging). Pull out the mains plug only directly at the plug, i.e. not by pulling at the mains lead.

Before picking up liquids, the filter bag must be removed and the function of the float switch checked. If foaming is observed, stop work immediately and empty the tank.
MAINTENANCE AND REPAIR
CAUTION!
Before cleaning and servicing the cleaner, always remove the mains plug.
Carry out only maintenance operations described in these operating instructions. Use only original Wap spare parts.
Do not make any technical modifications to the cleaner.
CAUTION!
Your safety could be endangered as a result!
For all other maintenance and repair work, please contact the Wap Service department or an authorised specialist workshop!
ELECTRICAL EQUIPMENT
Check the rated voltage of the cleaner before connecting it to the mains power supply. Ensure that the voltage specified on the rating plate corresponds to the local mains voltage.
When connected to the mains power supply with a mains lead of type H 07 RN-F 3G 1.5 mm², the cleaner may also be used outdoors.
When using an extension lead or replacing the mains lead, the lead type specified by the manufacturer must always be used.
We recommend that the power supply to the cleaner be connected via an earth-leakage circuit breaker which interrupts the power supply either if the earth leakage current exceeds 30mA for 30 ms, or it contains an earthing test current circuit.
When using an extension lead, observe the minimum cross-sections of the leads:
| Cable length m | Cross-section mm2 |
| up to 20 | 1.5 |
| 20 to 50 | 2.5 |
Always arrange the current-carrying parts (plug sockets, plugs and connectors) and lay extension leads so that the protection class of the cleaner is maintained.
CAUTION!
Never spray the top section of the cleaner with water: Danger for persons, danger of short circuits.
The latest edition of the IEC Regulations must be observed.
ALTO HEADQUARTERS
Incentive International A/S
Kongens Nytorv 28
P.O.Box 2064
1013 Copenhagen K
Tel.: +45 33 11 11 42
Fax: +45 33 93 46 36
E-mail: incentive@incentive-dk.com
SUBSIDIARIES
AUSTRALIA
ALTO Overseas Inc.
1B/8 Resolution Drive
P.O.Box 797
Caringbah, N.S.W. 2229
Tel.: +61 295 24 61 22
Fax: +61 295 24 52 56
AUSTRIA
24 Constellation Road
Rexdale
Ontario M9W 1K1
Tel.: +1 416 6 75 58 30
Fax: +1 416 6 75 69 89
CROATIA
Wap ALTO Strojevi za ciscenje, d.o.o.
Siget 18a
10020 Zagreb
Tel.: +385 16554144
Fax: +385 165 54 112
E-mail: admin.wap@wap-sistemi.hr
CZECH REPUBLIC
ALTO Cleaning Systems
(UK) Ltd.
Bowerbank Way
Gilwilly Industrial Estate, Penrith
Cumbria CA11 9BN
Tel.: +44 1 7 68 86 89 95
Fax: +44 1 7 68 86 47 13
E-mail: sales@alto-uk.com
JAPAN
Representative Office
5-2, Sakyo 1-Chome
631-0801 Nara City
ALTO Cleaning Systems, Inc.
12249 Nations Ford Road
28134 Pineville
Tel.: +1 704 971 1240
Fax:+17049711241
E-mail: info@altocsi.com
ALTO U.S. Inc.
16253 Swingley Ridge Road, Suite 200
63017-1544 Chesterfield, Missouri
Tel.: +1 636 530 0871
Fax: +1 636 530 0872
E-mail: info@alto-us.com
ALTO U.S. Inc.
2100 Highway 265
72764 Springdale, Arkansas
Tel.: +1 479 750 1000
Fax: +14797560719
E-mail: info@alto-us.com
ALTO U.S. Inc.
1100 Haskins Road
43402 Bowling Green
Tel.: +1 419 352 7
Fax:+14193537187
E-mail: info@alto-us.com
SB Station
SB Station Marathon
SB Tandem
SB Tandem Marathon

D Betriebsanleitung 2
GB Operating Instructions 8
F Notice d'utilisation 14
NL Gebruiksaanwijzing 20
Istruzioni sull'uso 26
N Driftsinstruks 32
S Bruksanvisning 38
DK Driftsvejledning 44
Käyttoohje 50
SLO Navodilo za uporabo 56
HR Uputstvo za rad 62
SK Prevádkový námod 68
CZ Provozní námod 74
PL Instrukcja obstugi 80
H Kezelésiutasítás 86
E Instrucciones de manejo 92
P Instruções de operação 98
GR O\nyieC\lambda$ europyiaC 104
TR Isletme kilavuzu 110



Total Cleaning ConfidenceTM

SB Station, SB Station Marathon
SB Tandem, SB Tandem Marathon
Beschreibung:
230V\~,50Hz
SB Station, SB Station Marathon
SB Tandem, SB Tandem Marathon
Description:
230V\~,50Hz
Directive CE relative aux machines 39/37/EG 10/2014, Directive CE relative a basso machine 39/37/EG 10/2014, Directive CE EMV 89/33/6/14
EU Declaration of Conformity
Self Service Vacuum Cleaner
Type:
SB Station, SB Station Marathon SB Tandem, SB Tandem Marathon
Description:
230V\~,50Hz
The design of the unit corresponds to following pertinent regulations:
EC Machine Directive 98/37/EG
EC Technical Directive 71/36/EU
EC EMV Directive 89/33/EGE
Applied harmonised standards:
EN 292
EN 60335-1, 60335-1 A6
EN 60335-2-69
EN 55014-1, EN 55014-2, EN 61000-3-2
Applied national standards and technical specifications:
ppa. Rau, Dipl. Eng. (FH) Head of Research and Development
Bellenberg, 23.06.1999

SB Station, SB Station Marathon SB Tandem, SB Tandem Marathon
Descrizione:
230V\~,50Hz
SB Station, SB Station Marathon SB Tandem, SB Tandem Marathon
Type:
230V\~,50Hz
Beschrijving:
EG-machinerichtigt
EG-kaagsamprinngstichtigt
EG-keitsverzinsung
98/37/EG 73/23/EG 89/336/EG
SB Station, SB Station Marathon SB Tandem, SB Tandem Marathon
Descripción:
230V\~,50Hz
La construction de laquina
a la quiesante norme
especillas:
Wap Reginsystemics Technology Ltd. & Co. Co. Ltd. 1-20th Ave. 2-8 D-89287 Bellenberg
Produco:
Modelo:
Descrição:
A construcciona maquina
A constitutive as següntes normas
especifica.
SB Station, SB Station Marathon
SB Tandem, SB Tandem Marathon
230V\~,50Hz
Eepaeoeiee eevpuuuevues nppepaepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepepe pe
Edouagobélece Ecbéne
mopadocypodae kaxyveon
Ee
Pw m m A.Rau
Yteu@ooc epuenmkuou mluuotc
SB SaugStation
SB Station, SB Station Marathon SB Tandem, SB Tandem Marathon
230V\~,50Hz
Oyjia mepi jmuovow EOK Oyjia oyuwn wouw EOK Oyjia mepi kauktoaaynuynuynic uauo
EN 292
EN 60335-1, 60335-1-A6
EN 60335-2-69
EN 55014-1, EN 55014-2
Wap Reginsystemics Technology Ltd. & Co. Co. Ltd. 1-20th Ave. 2-8 D-89287 Bellenberg
Produkt:
Type:
Beskrivelse:
SB Station, SB Station Marathon SB Tandem, SB Tandem Marathon
230V\~,50Hz
SQ450, SQ 550, SQ650, SQ651
IPX4 220-230V~
EF-maskindirektiv 98/37/EEC
EF-lapsveningsdirektiv 73/23/EEC
EF-direktiv elektromagnetisk kompatibilitet
98/37/EEC
73/23/EEC
89/336/EEC
EN 292
EN 60335-1, 60335-1 A6
FN 60335-2-69
EN 55014-1, EN 55014-2, EN 61000-3-2
DIN EN 60335-1
IEC 60335-2-69
Bellenberg, 23.06.1999

Wap Reginsystemics GmbH & Co. KGaA, 12043 Bielefeld-2-8 D-89287 Bellenberg
Produkt:
Typ:
Beskrivning:
Apparatus konstruktur motsvaran foliande tilampiga bestamselesse
Tillampade harmoniserade normer:
SB Station, SB Station Marathon
SB Tandem, SB Tandem Marathon
230V\~,50Hz
EG-maskindirektiv
EG-lagspanningsdirektiv
EG-direktiv EMK
EN 292
EN 60335-1,60335-1 A6
EN 60335-2-69
EN 55014-1, EN 55014-2, EN 61000-3-2
DIN EN 60335-1
IEC 60335-2-69
Bellenberg, 23.06.1999

SB Station, SB Station Marathon
SB Tandem, SB Tandem Marathon
230V\~,50Hz
EF-maskindirektiv
SB Station, SB Station Marathon
SB Tandem, SB Tandem Marathon
The SB Station is a self-service vacuum cleaner suitable for picking up dry, non-flammable dusts normally encountered when cleaning the inside of motor vehicles. Liquids and health-endangered dusts must not be picked up.
DESCRIPTION (FIG. 1)
1 Hose retractor
2 Coin verifier
3 Suction hose fitting
4 Crevice nozzle
5 Suction unit
6 Dirt tank
7 Main switch
8 Adapter ring
9 Lock for coin verifier slot
10 Distance basket
11 Cloth insert filter
SETTING UP THE STATION
- Release the SB Station from the pallet. NOTE!
Do not throw the packaging carton away. The drilling
pattern for mounting the SB Station is printed on the carton. (Fig. 2)
- Open the door.
Take the suction hoses out of the housing. - Lift the suction unit with the brackets and secure in place. (Fig. 3).
Take out the dirt tank and the accessories in the tank. - Mount the SB Station in the intended position using the installation materials supplied.
NOTE!
Ensure that the SB Station is mounted on flat, level ground.
necessary:
- Level using shims!
- Check that the door opens and closes easily!
Have the electrical connection made by a qualified electrician:
- Lay the lead (above 15 m, use lead with 2.5 mm² cross-section) along the bottom of the SB Station. Lay the lead into the terminal box and connect as shown in the circuit diagram.
FITTING THE SUCTION HOSES
SB Station and SB Sation Marathon:
- Insert the suction hose from the outside through the hose opening (approx. 80 cm, measured from the inner edge of the hose opening to the end of the suction hose). (Fig. 4)
SB Tandem and SB Tandem Marathon:
First fit the suction hose for cleaner A (Fig. 5).
- Insert the suction hose from the outside through the hose opening. For
- Cleaner A approx. 80 cm
- Cleaner B approx. 80 cm measured from the inner edge of the hose opening to the end of the suction hose. (Fig. 4)
FITTING THE CONNECTING ELBOW, HOSE HOLDER AND CREVICE NOZZLE
- Fit the adapter ring (Fig. 1, No. 8) over the connection on the dirt tank.
NOTE!
The connecting elbow opening should point upwards. (Fig. 5)
- Screw adapter fitting (Fig. 6, Item 2) approx. 35mm onto suction hose (Fig. 6, Item 1). Plug adapter fitting with suction hose into connecting elbow (Fig. 6, Item 3).
NOTE!
Push the suction hose into the housing only far enough that the suction unit can still swing freely when the suction hose is connected. This is important so that the suction unit fits airtight onto the dirt tank when lowered.
-
Secure the suction hose with the metal bracket. (Fig. 7).
-
Secure the hose bracket to the suction hose approx. 1.30m
from the end of the hose. (Fig. 8).
-
Remove screw from clamping piece and detach rope end. Guide the rope through the eye at the hose holder. Hook up rope end to clamping piece and secure with screw. (Fig. 9).
-
Screw the crevice nozzle onto the end of the hose (left-hand thread).
OPTIONAL ACCESSORIES
Hose holder
It is also possible to operate the SB Station without the hose retractor. Secure the hose holder to the existing bores with screws. After work, the hose is simply placed into the hose holder. (Fig. 10). Art. No. 43064
CAUTION!
Either the hose holder or the hose bracket should be installed as otherwise the suction hose handling is restricted.
Electronic coin tester

Allows the SB Station to be operated with different coins.
On request.
STARTING OPERATION
- Place the dirt tank into the station and lower the suction unit.
- Fit the suction hose with the adapter ring over the connection of the dirt tank.
Open the cover for the coin tester tube:
Pull the knob and turn through 90^ - the cover can now be opened (Fig. 11).
Pull up the cover until it is horizontal and secure with the flap holder (Fig. 12).
- Set the desired running time per coin at rotary knob 1 of the timer. (Fig. 13): 1 = 1 minute 10 = 10 minutes (Rotary knobs 2-4 are required only with electronic coin tester)
Close the cover for the coin tester tube:
- Push down the cover and turn the knob through 90^ - the latching pin engages.
(Continued --)

It is possible to secure access to the coin box with a padlock (not included in the scope of supply) (Fig. 14).
- Turn the main switch to position '1'. (Fig. 1, item 9)
To check the function, the suction turbine starts briefly. If the turbine does not start, remedy the cause --> See section "Troubleshooting".
THE FOLLOWING FUNCTIONS ARE ACTIVE WHEN THE STATION IS SWITCHED ON
SB-Station
SB-Station Marathon
- Insert a coin
- The pulse counter counts the number of coins inserted
- At the end of the preset time, the suction turbine switches off
- Manual test function: Pressing the button 'Test' (Fig. 13) on the timer pcb switches on the suction turbine briefly.
SB-Tandem
SB-TandemMarathon
- Insert a coin
- The push Buttons on the column start to flash.
- Select the left-hand or right-hand hose by pressing the corresponding button.
- The push-button of the selected side now lights up continuously and the suction turbine starts to run.
- The pulse counter counts the number of coins inserted
- At the end of the preset time, the
suction turbine switches off
- Manual test function: Pressing the button 'Test' (Fig. 13) on the timer pcb switches on the suction turbines briefly.
SWITCHING OFF
- Turn the main switch on the inside of the column to position '0'.
MAINTENANCE
Weekly/when necessary:
Cleaning and changing the cloth insert filter (Fig. 15)
- Turn the main switch to position „0".
- Before emptying the dirt tank, hit it gently with the palm of your hand so that dirt drops from the cloth insert filter into the dirt tank.
- Lift the suction unit with the bracket and secure it (Fig. 3).
- Remove suction hose with adapter ring from the connection of the dirt tank.
- Remove the dirt tank.
- Remove the distance basket.
- Remove the cloth insert filter, brush it
with a soft brush and check that it is not damaged.
NOTE:
The cloth insert filter can also be cleaned by dipping it in a slightly soapy solution at 30(C. Be careful not to damage the surface of the cloth insert filter and allow it to dry thoroughly after washing it.
- If necessary, replace a damaged cloth insert filter with a new one. Dispose of damaged cloth insert filter according to regulations.
- Insert cloth insert filter in the dirt tank in such a way that the „Do not hit“ label is in front of the suction opening of the dirt tank.
- Insert the distance basket in the cloth insert filter.
Lower the suction unit.
NOTE:
Ensure that the wire ring of the cloth insert filter is pulled over the edge of the dirt tank and that the dirt tank is fitted air-tight on to the suction unit.
For re-orders:
Cloth insert filter
Art. No. 34106
Cleaning the coin tester
To ensure trouble-free functioning of the coin tester, the coin slot should be cleaned at regular intervals with a cloth soaked in white spirit.
IMPORTANT! Never oil the coin tester!
SPARE PARTS
Suction hose complete
Art.No. 64084
Crevicenozzle
Art.No. 64386
GUARANTEE
Our general terms and conditions apply to the guarantee and warranty.
Changes in line with technical innovation reserved.
TROUBLESHOOTING
Fault
Cleaner does not start
Reduced suction power
Cause
Fuse or r.c.c.b of the power supply tripped
Coin tester soiled or defective
Suction turbine, pushbutton or timerdefectiveSuction hose clogged
Cloth insert filter soiled
Dirt tank full
Remedy
- Replace fuse or reset r.c.c.b
Clean or replace coin tester
Call Service
Clean suction hose
See section "Clean/ replace cloth insert filter"
Empty dirt tank
Hose retractor defective
Retractor line broken
Call Service
| SB-Station SB Station Marathon | SB-Tandem SB Tandem Marathon | ||
| Voltage | V/Hz | 230/50-60Hz | 230/50-60Hz |
| Power consumption, max. | W | 1400 | 2800 (Tandem) |
| 1200 (Marathon) | 2400 (Tandem GB,CH) | ||
| 2000 (Tandem DK) | |||
| 2400 (Tandem Marathon) | |||
| Fuse | A | 16 | 16 |
| 13 (GB,CH) | 13 (GB,CH) | ||
| 10 (DK) | 10 (DK) | ||
| Volumetric flow (air), max.. | l/min. | 4000 | 2 x 4000 (Tandem) |
| 4200 (Marathon) | 2 x 3600 (Tandem GB,CH) | ||
| 2 x 3000 (Tandem DK) | |||
| 2 x 4200 (Tandem Marathon) | |||
| Vacuum, max. | Pa | 23500 | 23500 |
| 25000 (Marathon) | 25000 (Marathon) | ||
| Sound level 1 m from the Station | dB(A) | 75 | 75 |
| Protection class | I | I | |
| Type of protection | IP X4 | IP X4 | |
| Interference suppression level | N | N | |
| Suction hose - length | m | 5 | 2 x 5 |
| - diameter | mm | 50 | 50 |
| Tank volume | l | 30 | 2 x 30 |
| Depth | m | 0.83 | 1.19 |
| Width | m | 0.55 | 0.55 |
| Height | m | 2.04 | 2.04 |
| Weight, complete | kg | 90 | 115 |
ALTO HEADQUARTERS
Incentive International A/S
Kongens Nytorv 28
P.O.Box 2064
1013 Copenhagen K
Tel.: +45 33 11 11 42
Fax: +45 33 93 46 36
E-mail: incentive@incentive-dk.com
SUBSIDIARIES
AUSTRALIA
ALTO Overseas Inc.
1B/8 Resolution Drive
P.O.Box 797
Caringbah, N.S.W. 2229
Tel.: +61 2 95 24 61 22
Fax: +61 2 95 24 52 56
AUSTRIA
24 Constellation Road
Rexdale
Ontario M9W 1K1
Tel.: +1 41 66 75 58 30
ALTO Cleaning Systems
(UK) Ltd.
Bowerbank Way
Gilwilly Industrial Estate, Penrith
Cumbria CA11 9BN
Tel.: +44 1 7 68 86 89 95
Fax: +44 1 7 68 86 47 13
E-mail: sales@alto-uk.com
HONG KONG
ALTO Hong Kong
RM 602, Tower B,
Regent Ctr.
70, Ta Chuen Ping Street
Kwai Chung
Hong Kong
Tel.: +852 26 10 10 42
Fax: +852 26 10 10 47
E-mail: waphk@netvigator.com
JAPAN
Representative Office
Naruse-build 4F
7-2 Shinbashi 1-Chome, Minato-Ku
J-Tokyo 105-004
Tel.: +81 3 35 69 38 07
Fax: +81 3 35 69 38 08
E-mail: alto-jpn@nifty.com
NETHERLANDS
Bowling Green, Ohio 43402
Tel.: +1 41 93 52 75 11